...

Gas Steam Boiler installation with Bradford White Gas 50 gallon water heater

This client had a cracked and failed gas Weil-McLain steam boiler that was way oversized for this home in Chelmsford Massachusetts. It failed at 11 years due to constant short cycling. The 50 gallon gas water heater was also illegally…
Gas Steam Boiler installation with Bradford White Gas 50 gallon water heater

This client had a cracked and failed gas Weil-McLain steam boiler that was way oversized for this home in Chelmsford Massachusetts. It failed at 11 years due to constant short cycling. The 50 gallon gas water heater was also illegally installed and was very dangerously venting carbon monoxide flue gases into the home. We removed both of the pieces of equipment and properly sized a new Peerless Gas fired Steam boiler made in USA as well as a new Bradford White 50 gallon low boy gas water heater to properly fit into the chimney. We added the proper combination carbon monoxide & smoke detector as well. Then we replaced all of the steam radiator vents. Lots of people tell me they like the steam heat because it makes it moist in the house. Well if that is happening that is an indication that you your steam boiler, or the radiators or the vents are bad. The vents are only there to allow air to escape as the water boils into steam and rises up through the house to the radiators. Once the steam reaches the radiator vents they are supposed to click shut and trap the steam in the radiator until the steam heats the radiator and once the steam cools back down and turns back into water, the vents will then open and aid the water to drain back to the boiler to be reused in making steam again. If you would like to upgrade your home please go to our website and fill out the request service form and I’ll make and appointment with you to come out and do a home evaluation and discuss and price out a replacement upgrade system. https://dibaccoplumbing.com/contact


All right here we are in chelmsford mass We have a client here who has a 11 year Old will mclean Steam boiler that has cracked and failed Um prematurely too We’ve discovered that this boiler was Grossly oversized for the house and the Need so this thing suffered from Short cycling And we also discovered that whoever Installed it Could not have been a plumber because They tied in a water heater And then piped the vent downward which Is absolutely illegal and dangerous and Deadly because then carbon monoxide gas Can flow right out of the flue collector Here The draft damper rather and allow the Carbon monoxide to go through the house Now this is an old Drafty house so i think that’s what Saved their lives and they didn’t die From carbon monoxide but we’re going to Fix all of that up today First thing i got to do is get this old Unit out My son mike is on his way to pick up all The materials i’m going to cut out All of the old piping here and get ready To get this boiler moved out of here We’ll talk to you later All right we’re at the final stretch Here we’ve got big frank bonyani

Getting this baby wired up Here’s our new Steam boiler peerless Now the vent is no longer Going upside down New water heater There you go [Music] Here we are now with the finished Product we got our properly sized Peerless steam boiler in here Everything’s heating up nicely three Inch riser steam riser there going into Our header Automatic fill with a bypass Piped in if you wanted to manually add Water We have a blow down purge station For skimming We’ve added the boiler cleaner so That’ll clean all the rust and sediment Out of the system It’s wired up the new water heater Properly vented No more carbon monoxide Risk in the house and we even added a Code required Smoke and cover the moxie detector there If you’re interested in getting your System replaced please go to Debacleplumbing.com I’d be happy to come out and give you a In-home evaluation Take care

Share:

More Posts

DiBacco_Plumbing_Summer_Plumbing_Tips

Summer Plumbing Tips: Keep Your Home Comfortable

As the summer months approach, homeowners in Massachusetts need to ensure their plumbing and HVAC systems are in top condition, including regular maintenance of the chimney and vent systems. to keep their houses cool and comfortable, incorporating radiators as part of the heating system. By implementing various strategies, you can optimize your heating, ventilation, and

DiBaccoPlumbing_Genrac_Standby_Generator_26kW

The Environmental Benefits of Generac Home Standby Generators

Generac home standby generators are not just a solution for power outages; they also play a significant role in benefiting the environment. Let’s take a closer look at how these generators contribute to environmental sustainability. How Do Generac Home Standby Generators Help The Environment? One of the key advantages of Generac home standby generators is

DiBacco_Plumbing_Ultimate_to_Home_Standby_Generator_GENERAC

The Ultimate guide to home standby generators with GENERAC

Home standby generators have become an essential backup power solution for homeowners looking to ensure uninterrupted power supply during outages. One of the key players in the generator market is Generac, which stresses the importance of Generac’s standby generators in ensuring the efficiency and safety of home and business environments. known for its innovative and

DiBaccoPlumbing_SPRING PLUMBING MAINTENANCE

Spring Plumbing Maintenance Checklist for New Hampshire Homeowners

As the seasons change and the cold winter gives way to the warmth of spring, it’s essential for New Hampshire homeowners to ensure their plumbing systems are in top condition. A thorough spring plumbing maintenance checklist can help prevent costly repairs and water damage down the line. Maintenance Checklist Regular maintenance is key to keeping

Scroll to Top